Related Experiment Video
Updated: Oct 12, 2025

Computerized Adaptive Testing System of Functional Assessment of Stroke
Published on: January 7, 2019
Validity and reliability of patient reported outcomes measurement information system computerized adaptive tests in
Mitra Moazzami1, Patricia Katz2, Dennisse Bonilla3
1Department of Medicine, 43989The George Washington University School of Medicine and Health Sciences, Washington, DC, USA.
Background:
The evaluation of Patient Reported Outcomes Measurement Information System (PROMIS) computerized adaptive test (CAT) in adults with systemic lupus erythematous (SLE) is an emerging field of research. We aimed to examine the test-retest reliability and construct validity of the PROMIS CAT in a Canadian cohort of patients with SLE.
Methods:
Two hundred twenty-seven patients completed 14 domains of PROMIS CAT and seven legacy instruments during their clinical visits. Test-retest reliability of PROMIS was evaluated 7-10 days from baseline using intraclass correlation coefficient (ICC (2; 1)). The construct validity of the PROMIS CAT domains was evaluated against the commonly used legacy instruments, and also in comparison to disease activity and disease damage using Spearman correlations. A multitrait-multimethod matrix (MMM) approach was used to further assess construct validity comparing selected 10 domains of PROMIS and SF-36 domains.
Results:
Moderate to excellent reliability was found for all domains (ICC [2;1] ranging from lowest, 0.66 for Sleep Disturbance and highest, 0.93 for the Mobility domain). Comparing seven legacy instruments with 14 domains of PROMIS CAT, moderate to strong correlations (0.51-0.91) were identified. The average time to complete all PROMIS CAT domains was 11.7 min. The MMM further established construct validity by showing moderate to strong correlations (0.55-0.87) between select PROMIS and SF-36 domains; the average correlations from similar traits (convergent validity) were significantly greater than the average correlations from different traits.
Conclusions:
These results provide evidence on the reliability and validity of PROMIS CAT in SLE in a Canadian cohort.
Related Concept Videos
Reliability and Validity
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...

