A Comparison of Incomplete Resection Rate of Large and Small Colorectal Polyps by Cold Snare Polypectomy
Xianzong Ma1, Xiutang Feng2, Yangjie Li2
1Department of Gastroenterology, Seventh Medical Center of Chinese PLA General Hospital, Beijing, China; Chinese PLA General Hospital, Beijing, China.
Background & Aims:
There are limited data regarding the safety and efficacy of cold snare polypectomy (CSP) for large colorectal polyps. We evaluated factors affecting the clinical outcomes of CSP for polyps between 5 and 15 mm in size.
Methods:
This was a prospective single-center observational study involving 1000 patients undergoing colonoscopy. Polyps (5-15 mm) were removed using CSP, and biopsies were taken from the resection margin. The primary outcome was the incomplete resection rate (IRR), and was determined by the presence of residual neoplasia on biopsy. Correlations between IRR and polyp size, morphology, histology, and resection time were assessed by generalized estimating equation model.
Results:
A total of 440 neoplastic polyps were removed from 261 patients. The overall IRR was 2.27%, 1.98% for small (5-9 mm) vs 3.45% for large (10-15 mm) polyps (P = .411). In univariate analysis, the IRR was more likely to be related to sessile serrated lesions (odds ratio [OR], 6.93; 95% confidence interval [CI], 1.88-25.45; P = .004), piecemeal resection (OR, 11.83; 95% CI, 1.20-116.49; P = .034), and prolonged resection time >60 seconds (OR, 7.56; 95% CI, 1.75-32.69; P = .007). In multivariable regression analysis, sessile serrated lesions (OR, 6.45; 95% CI, 1.48-28.03; P = .013) and resection time (OR, 7.39; 95% CI, 1.48-36.96; P = .015, respectively) were independent risk factors for IRR. Immediate bleeding was more frequent with resection of large polyps (6.90% vs 1.42%; P = .003). No recurrence was seen on follow-up colonoscopy in 37 cases with large polyps.
Conclusions:
CSP is safe and effective for removal of colorectal polyps up to 15 mm in size, with a low IRR. (ClinicalTrials.gov; Number: NCT03647176).