Related Experiment Video
Updated: Oct 12, 2025

Author Spotlight: Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Published on: March 17, 2023
A review of occupancy-based building energy and IEQ controls and its future post-COVID
Prashant Anand1, David Cheong2, Chandra Sekhar2
1Department of Architecture and Regional Planning, IIT, Kharagpur, India.
Abstract:
Occupancy schedules and density can have a substantial influence on building plug, lighting, and air conditioning energy usage. In recent years, the study related to occupancy and its impact on building energy consumption has gained momentum and is also promoted by ASHRAE as it has created a multi-disciplinary group to encourage a comprehensive study of occupant behaviour in buildings. Past studies suggest that building systems do not consume the same energy and provide similar Indoor Environmental Quality (IEQ) to their designed specifications due to inaccurate assumptions of occupants and their behaviour. Supplying ASHRAE 62.1 specified minimum required ventilation based on accurate occupancy may lead to significant air-conditioning energy savings. However, the same strategy is not suitable in the current time since minimum required ventilation may not be sufficient to mitigate the SARS-CoV-2 virus spread in confined spaces. High-temperature cooling augmented with elevated air movement across an acceptable range of velocity can maintain the health and comfort of occupants by providing higher ventilation and without an energy penalty. The analysis of the literature highlights strengths, weaknesses, and key observations about the existing occupancy monitoring and occupancy-based building system control methods to help in the direction of future occupancy-based research.
Related Concept Videos
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Insulation Coordination
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Movement Joints in Buildings