The Coris BioConcept COVID 19 Ag Respi-Strip, a field experience feedback
Assaf Mizrahi1, Jean-Claude Nguyen Van2, Najoua El Helali2
1Service de Microbiologie clinique, Groupe hospitalier Paris Saint Joseph, Paris, France; Institut Micalis UMR 1319, Université Paris-Saclay, INRAe, AgroParisTech, Châtenay Malabry, France.
Abstract:
This communication described how the Coris BioConcept COVID-19 Ag Respi-Strip test (Coris-Ag) was implemented in the workflow of our clinical microbiology laboratory for COVID-19 diagnosis. The diagnostic performance statistics (sensitivity, specificity) of the Coris-Ag were evaluated against a gold standard, the RealStar SARS-CoV-2 RT-PCR kit 1.0. Additionally, the effect of reading the Coris-Ag results at 30 min was compared to reading at 15 min. The Coris-Ag was performed on a total of 294 patients during two periods; 158 patients were tested during period 1 at the peak of the pandemic (April 6th to April 10th 2020) which returned a positivity rate of 17.1 %, and 136 patients during period 2 (April 12th to April 16th 2020) which returned a positivity rate of 11 %. Compared to the RT-PCR, the 15-minute Coris-Ag readings resulted in a sensitivity of 59.3 % with a 100 % specificity for the period 1 patients (n = 158) while the sensitivity decreased to 20 % for the period 2 patients (n = 136). The overall sensitivity was 38.1 % for both periods (n = 294). The corresponding 30-minute readings produced a 7 % increase in sensitivity with a specificity of 100 % (n = 294). The sensitivity of the strip test (15-min reading) for high viral loads (Ct <25) was 84.6 %.
More Related Videos
07:13Swabbing the Urban Environment - A Pipeline for Sampling and Detection of SARS-CoV-2 From Environmental Reservoirs
Published on: April 9, 2021
08:21Cell-Free Dot Blot as a Practical and Adaptable Immunoassay Platform for the Detection of Antibody Response in Human and Animal Sera
Published on: May 23, 2025
Related Concept Videos
Pulse Assessment Sites
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Serum Laboratory Studies, Stool Test, Breath Test
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: