Related Experiment Video
Updated: Oct 12, 2025

Early Detection of Cyanobacterial Blooms and Associated Cyanotoxins using Fast Detection Strategy
Published on: February 25, 2021
Synergistic data fusion of multimodal AOD and air quality data for near real-time full coverage air pollution
Ke Li1, Kaixu Bai2, Zhengqiang Li3
1Key Laboratory of Geographic Information Science (Ministry of Education), School of Geographic Sciences, East China Normal University, Shanghai, 200241, China.
Abstract:
Data gaps in satellite aerosol optical depth (AOD) retrievals pose a huge challenge in near real-time air quality assessment. Here, we present a multimodal aerosol data fusion approach to integrate multisource AOD and air quality data for the generation of full coverage AOD maps at hourly resolution. Specifically, data gaps in each Himawari-8 AOD snapshot were partially filled by merging all available daytime AOD snapshots, and these partially gap-filled AOD maps were then fused with coarse yet spatially complete numerical AOD simulations to generate full coverage AOD imageries. Ground-based air quality measurements, including concentrations of PM2.5, PM10, NO2, and SO2, were simultaneously assimilated into gridded AOD fields to enhance the overall data accuracy. A practical implementation of the proposed method was illustrated by generating hourly full-coverage AOD maps in China from 2015 to 2020, and the validation results indicate this new AOD dataset agreed well with ground-based AOD measurements (R = 0.83), from which a ubiquitous AOD decreasing trend was revealed, especially during the noontime. Moreover, the hourly resolution and full-coverage advantages of this AOD dataset allow us to better assess spatiotemporal variations of PM10 and PM2.5 pollution that occurred in China. Overall, the proposed method paves a new way as big data analytics to advance regional air pollution assessment given the full coverage capacity and enhanced accuracy of the resulting AOD and PM concentration data.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
08:23Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry
Published on: June 14, 2018
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...