Adaptive MOMEDA based on improved advance-retreat algorithm for fault features extraction of axial piston pump
Chaoang Xiao1, Hesheng Tang2, Yan Ren1
1College of Mechanical and Electrical Engineering, Wenzhou University, Wenzhou, 325035, China.
Abstract:
The fault information of axial piston pump bearings is inevitably submerged by violent natural periodic impulses. Therefore, an accurate extraction of fault impulses remains a challenging problem. A hybrid method of MOMEDA and TEO is proposed to extract periodic impulses in this study. Firstly, the deconvolution periods of multiple periodic components in the original vibration signals are analysed using Kurtosis. Then, an advance-retreat algorithm is used to optimize the filter length of MOMEDA. After multiple input parameters are determined adaptively, the MOMEDA is used to enhance the various periodic impulses respectively. Finally, TEO demodulation is employed to further obtain fault frequencies. Experimental vibration data is used to verify the advantages of this method for periodic impulses extraction. The results are then compared with traditional deconvolution and decomposition techniques to prove the superior performance of the proposed approach in terms of its better accuracy and reduced processing time.
More Related Videos
Related Concept Videos
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Fast Decoupled and DC Powerflow
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
Root-Locus Method
This system can be represented by a block...
Application of Pascal's Law
Hydraulic systems are used to operate automotive brakes, hydraulic jacks, and numerous other mechanical systems. We can derive a relationship between the forces in a simple hydraulic system...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...