Related Experiment Video
Updated: Oct 12, 2025

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Electrical Impedance Tomography Analysis Between Two Similar Respiratory System Compliance During Decremetal PEEP
Po-Lan Su1,2, Wei-Chieh Lin2, Yen-Fen Ko1
1Institute of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
Purpose:
The positive end-expiratory pressure (PEEP) level with best respiratory system compliance (Crs) is frequently used for PEEP selection in acute respiratory distress syndrome (ARDS) patients. On occasion, two similar best Crs (where the difference between the Crs of two PEEP levels is < 1 ml/cm H2O) may be identified during decremental PEEP titration. Selecting PEEP under such conditions is challenging. The aim of this study was to provide supplementary rationale for PEEP selection by assessing the global and regional ventilation distributions between two PEEP levels in this situation.
Methods:
Eight ARDS cases with similar best Crs at two different PEEP levels were analyzed using examination-specific electrical impedance tomography (EIT) measures and airway stress index (SIaw). Five Crs were measured at PEEP values of 25 cm H2O (PEEP25), 20 cm H2O (PEEP20), 15 cm H2O (PEEPH), 11 cm H2O (PEEPI), and 7 cm H2O (PEEPL). The higher PEEP value of the two PEEPs with similar best Crs was designated as PEEPupper, while the lower designated as PEEPlower.
Results:
PEEPH and PEEPI shared the best Crs in two cases, while similar Crs was found at PEEPI and PEEPL in the remaining six cases. SIaw was higher with PEEPupper as compared to PEEPlower (1.06 ± 0.10 versus 0.99 ± 0.09, p = 0.05). Proportion of lung hyperdistension was significantly higher with PEEPupper than PEEPlower (7.0 ± 5.1% versus 0.3 ± 0.5%, p = 0.0002). In contrast, proportion of recruitable lung collapse was higher with PEEPlower than PEEPupper (18.6 ± 4.4% versus 5.9 ± 3.7%, p < 0.0001). Cyclic alveolar collapse and reopening during tidal breathing was higher at PEEPlower than PEEPupper (34.4 ± 19.3% versus 16.0 ± 9.1%, p = 0.046). The intratidal gas distribution (ITV) index was also significantly higher at PEEPlower than PEEPupper (2.6 ± 1.3 versus 1.8 ± 0.7, p = 0.042).
Conclusions:
PEEPupper is a rational selection in ARDS cases with two similar best Crs. EIT provides additional information for the selection of PEEP in such circumstances.
Supplementary Information:
The online version contains supplementary material available at 10.1007/s40846-021-00668-2.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Acute Respiratory Failure-IV