Related Experiment Video
Updated: Oct 12, 2025

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Receiver operating characteristic curve analysis of arteriovenous dialysis access flow using ultrasound
Erwin Yii1, Ming Kon Yii1,2, Stephen Thwaites2
1Department of Surgery, School of Clinical Sciences at Monash Health, Monash University, Clayton, Victoria, Australia.
Backgrounds:
Despite numerous studies investigating the use of ultrasound (US) in assessing arteriovenous fistulas (AVF), there are no universally agreed threshold flow velocities in diagnosing significantly abnormal flow that are useful in predicting thrombotic flow-related dysfunction. This study evaluates a predictive model using receiver operating characteristic curve (ROC) analyses to establish threshold velocities.
Methods:
Five hundred and eleven US scans were analysed. ROC curves were used to determine the optimal threshold time average mean velocity (TAMV), peak systolic velocity (PSV) and end diastolic velocity (EDV) of the brachial artery supplying the AVF in determining the need for intervention or thrombosis within 3 months of the scans. Estimated flow volume (FV) ROC was used as an evaluative comparison.
Results:
There were 356 negative and 155 positive scan results in relation to the need for intervention or thrombosis. Empirical flow velocity parameters of TAMV, EDV and PSV were analysed using ROC curves, yielding an area under the curve (AUC) of 0.95, 0.92 and 0.86, respectively. FV ROC analysis yields a comparative AUC of 0.90. A TAMV cut-off at 48.6 cm/s yielded the highest AUC. Subgroup analysis yielded an optimal TAMV cut-off of 45 cm/s for forearm and 49 cm/s for arm AVF. The EDV was also highly predictive of outcomes. PSV has the lowest accuracy.
Conclusion:
The TAMV of inflow brachial artery to AVF is highly predictive of outcomes of thrombotic flow-related dysfunction. Our study confirms TAMV cut-offs of 45 cm/s for forearm and 49 cm/s for arm AVF. These results require prospective validation.
More Related Videos
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
06:38Early Detection of Drug-Induced Renal Hemodynamic Dysfunction Using Sonographic Technology in Rats
Published on: March 11, 2016
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Hemodialysis I: Introduction