Reliability-aware subcarrier mapping strategy of QC-LDPC encoded symbols in bandwidth-limited IM/DD OFDM systems

Optics Express
|November 23, 2021
PubMed

Related Concept Videos

Frequency-Domain Interpretation of PD Control01:24

Frequency-Domain Interpretation of PD Control

Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
187
Linear Approximation in Frequency Domain01:26

Linear Approximation in Frequency Domain

Linear systems are characterized by two main properties: superposition and homogeneity. Superposition allows the response to multiple inputs to be the sum of the responses to each individual input. Homogeneity ensures that scaling an input by a scalar results in the response being scaled by the same scalar.
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
165
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
200
Characteristics of Series Resonant Circuit01:24

Characteristics of Series Resonant Circuit

Series resonance occurs in a circuit containing inductive (L), capacitive (C), and resistive (R) elements connected sequentially. At the resonance frequency, the inductive and capacitive reactances are equal in magnitude but opposite in sign, effectively canceling each other. This causes the circuit's impedance is minimal, primarily determined by the resistance R. The resonant frequency of an RLC circuit is defined as:
351
Bandpass Sampling01:17

Bandpass Sampling

In signal processing, bandpass sampling is an effective technique for sampling signals that have most of their energy concentrated within a narrow frequency band. This type of signal is known as a bandpass signal. The key principle of bandpass sampling involves sampling the signal at a rate that is greater than twice the signal's bandwidth to prevent aliasing.
A bandpass signal has a spectrum with a lower frequency limit, denoted as ω1, and an upper frequency limit, denoted as ω2....
280
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
284