Related Experiment Video
Updated: Oct 12, 2025

Microprobe Capillary Electrophoresis Mass Spectrometry for Single-cell Metabolomics in Live Frog Xenopus laevis Embryos
Published on: December 22, 2017
Pseudophase microextraction for in-line sample concentration in micellar electrokinetic chromatography
Raymond B Yu1, Joselito P Quirino1
1Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences-Chemistry, University of Tasmania, Hobart, Tasmania, 7001, Australia.
Abstract:
Pseudophase microextraction (PPME) as a simple in-line sample concentration technique in micellar electrokinetic chromatography (MEKC) is presented. In contrast to popular electric-field driven stacking techniques in MEKC such as sweeping, PPME is pressure-driven. The technique afforded up to 403-2968x improvements in peak heights for fenoprop, dichlorprop, 1- and 2-naphthol compared to typical injection. Under the same MEKC conditions, the improvements in PPME were up to 23-59x better compared to sweeping. Briefly in PPME, the entire capillary was loaded (up to 20 capillary volumes) with the sample prepared in a dilute solution of cetyltrimethylammonium bromide ([CTAB] > critical surface aggregation concentration). The CTAB formed aggregates at the inner capillary walls and these aggregates acted as a stationary chromatographic pseudophase. After clean-up via flushing the capillary with purified water, the MEKC background solution (BGS) with sodium dodecyl sulfate was then introduced by pressure from the outlet end to elute the retained analytes. The analytes concentrate at front of the BGS and the front was moved to the inlet end of the capillary prior to MEKC. Optimization strategies and current limitations in PPME-MEKC are described. The linear ranges using a 4 capillary volume sample load obtained for fenoprop, dichlorprop, 1- and 2-naphthol were between 1 and 160 ng/mL (r2s ≥ 0.996), LOQs = 1-2.5 ng/mL and repeatability %RSDs (n = 6) were ≤5% (intra-day) and ≤7% (inter-day) (using low analyte concentrations 1-5x LOQ). PPME-MEKC with simple dilution of fortified real samples (no off-line sample concentration) was also able to detect low levels of dichlorprop (10 ng/mL, limit set in Australia) and 1- and 2-naphthol (7.5-15 ng/mL) in a drinking water and natural water sample, respectively (% recovery = 84-108%). The concept of PPME may find use in other modes of capillary electrophoresis and other nano-microscale separations.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Ion-Exchange Chromatography
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
High-Performance Liquid Chromatography: Elution Process

