Related Experiment Video
Updated: Oct 12, 2025

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
A CT-less approach to quantitative PET imaging using the LSO intrinsic radiation for long-axial FOV PET scanners
Mohammadreza Teimoorisichani1, Vladimir Panin1, Harold Rothfuss1
1Siemens Medical Solutions USA, Inc., Knoxville, Tennessee, USA.
Purpose:
Long-axial field-of-view (FOV) positron emission tomography (PET) scanners have gained a lot of interest in the recent years. Such scanners provide increased sensitivity and enable unique imaging opportunities that were not previously feasible. Benefiting from the high sensitivity of a long-axial FOV PET scanner, we studied a computed tomography (CT)-less reconstruction algorithm for the Siemens Biograph Vision Quadra with an axial FOV of 106 cm.
Methods:
In this work, the background radiation from radioisotope lutetium-176 in the scintillators was used to create an initial estimate of the attenuation maps. Then, joint activity and attenuation reconstruction algorithms were used to create an improved attenuation map of the object. The final attenuation maps were then used to reconstruct quantitative PET images, which were compared against CT-based PET images. The proposed method was evaluated on data from three patients who underwent a flurodeoxyglucouse PET scan.
Results:
Segmentation of the PET images of the three studied patients showed an average quantitative error of 6.5%-8.3% across all studied organs when using attenuation maps from maximum likelihood estimation of attenuation and activity and 5.3%-6.6% when using attenuation maps from maximum likelihood estimation of activity and attenuation correction coefficients.
Conclusions:
Benefiting from the background radiation of lutetium-based scintillators, a quantitative CT-less PET imaging technique was evaluated in this work.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
10:48PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET