Related Experiment Video
Updated: Oct 12, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Transcutaneous and End-Tidal CO₂ Measurements in Hypoxia and Hyperoxia
Abstract:
BACKGROUND: Transcutaneous measurement of carbon dioxide (CO₂) has been proposed for physiological monitoring of tactical jet aircrew because in some clinical settings it mirrors arterial CO₂ partial pressure (Paco₂). End-tidal monitoring in laboratory settings is known to give high-fidelity estimates of Paco₂.METHODS: The correspondence between end-tidal (PETco₂) and transcutaneous Pco₂ (tcPco₂) was examined in healthy volunteers under laboratory conditions of hyperoxia and hypoxia. Rest and exercise, skin heating and cooling, hyperventilation, and induced CO₂ retention were employed.RESULTS: Neither measure followed all known changes in Paco₂ and tcPco₂ changed when the skin temperature near the probe changed. Bland-Altman analysis showed significant nonzero slopes under most conditions. Regression analysis indicated that oxygen partial pressure (Po₂) in tissue measured as transcutaneous Po₂ (tcPo₂) is an important explanatory variable for tcPco₂ in addition to PETco₂, and that local skin temperature also has an effect. Additionally, absorption atelectasis from breathing 100% O₂ may cause PETco₂ to deviate from Paco₂.DISCUSSION: Even as a trend indicator for Paco₂, tcPco₂ is not useful under conditions that resemble those in the highly dynamic tactical jet aircraft environment. PETco₂ is also not a good indicator of CO₂ status in pilots who breathe nearly 100% O₂.Shykoff BE, Lee LR, Gallo M, Griswold CA. .
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Carbon Dioxide Transport in the Blood
Forms of CO2 Transport
1. Dissolved in plasma: A small percentage (7-10%) of CO2 is transported and dissolved directly in the plasma.
2. Carbaminohemoglobin: Just over 20% of CO2 is chemically bound to...

