Related Experiment Video
Updated: Oct 12, 2025

A Standardized Method for Measurement of Elbow Kinesthesia
Published on: October 10, 2020
Telemedical percussion: objectifying a fundamental clinical examination technique for telemedicine
Roman Krumpholz1, Jonas Fuchtmann2, Maximilian Berlet2,3
1Research Group MITI - Minimally Invasive Interdisciplinary Therapeutical Intervention, Technical University Munich, Munich, Germany. roman.krumpholz@tum.de.
Purpose:
While demand for telemedicine is increasing, patients are currently restricted to tele-consultation for the most part. Fundamental diagnostics like the percussion still require the in person expertize of a physician. To meet today's challenges, a transformation of the manual percussion into a standardized, digital version, ready for telemedical execution is required.
Methods:
In conjunction with a comprehensive telemedical diagnostic system, in which patients can get examined by a remote-physician, a series of three robotic end-effectors for mechanical percussion were developed. Comprising a motor, a magnetic and a pneumatic-based version, the devices strike a pleximeter to perform the percussion. Emitted sounds were captured using a microphone-equipped stethoscope. The 84 recordings were further integrated into a survey in order to classify lung and non-lung samples.
Results:
The study with 21 participants comprised physicians, medical students and non-medical-related raters in equal parts. With 71.4% correctly classified samples, the ventral motorized device prevailed. While the result is significantly better compared to a manual or pneumatic percussion in this very setup, it only has a small edge over the magnetic devices. In addition, for all ventral versions non-lung regions were rather correctly identified than lung regions.
Conclusion:
The overall setup proves the feasibility of a telemedical percussion. Despite the fact, that produced sounds differ compared to today's manual technique, the study shows that a standardized mechanical percussion has the potential to improve the gold standard's accuracy. While further extensive medical evaluation is yet to come, the system paves the way for future uncompromised remote examinations.
Related Concept Videos
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...
Data Collection III
The principles to begin the physical assessment include conducting a comprehensive or problem-related history in a quiet, well-lit room, emphasizing privacy and comfort for the...
Nursing Assessment of the Genitourinary System III: Percussion and Auscultation
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...