Background:
Non-invasive mechanical ventilation (NIV) use in patients admitted with acute respiratory failure due to COPD exacerbations (AECOPDs) varies significantly between hospitals. However, previous literature did not account for patients' illness severity. Our objective was to examine the variation in risk-standardized NIV use after adjusting for illness severity.
Methods:
We retrospectively analyzed AECOPD hospitalizations from 2011 to 2017 at 106 acute-care Veterans Health Administration (VA) hospitals in the USA. We stratified hospitals based on the percentage of NIV use among patients who received ventilation support within the first 24 hours of admission into quartiles, and compared patient characteristics. We calculated the risk-standardized NIV % using hierarchical models adjusting for comorbidities and severity of illness. We then stratified the hospitals by risk-standardized NIV % into quartiles and compared hospital characteristics between quartiles. We also compared the risk-standardized NIV % between rural and urban hospitals.
Results:
In 42,048 admissions for AECOPD over 6 years, the median risk-standardized initial NIV % was 57.3% (interquartile interval [IQI]=41.9-64.4%). Hospitals in the highest risk-standardized NIV % quartiles cared for more rural patients, used invasive ventilators less frequently, and had longer length of hospital stay, but had no difference in mortality relative to the hospitals in the lowest quartiles. The risk-standardized NIV % was 65.3% (IQI=34.2-84.2%) in rural and 55.1% (IQI=10.8-86.6%) in urban hospitals (p=0.047), but hospital mortality did not differ between the two groups.
Conclusion:
NIV use varied significantly across hospitals, with rural hospitals having higher risk-standardized NIV % rates than urban hospitals. Further research should investigate the exact mechanism of variation in NIV use between rural and urban hospitals.
More Related Videos
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation I: Indication and Settings
Acute Respiratory Failure-III
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: