Biomechanical effects of Teuscher activator in hyperdivergent Class II malocclusion treatment: A finite element
Marta Jorge1, Mário Vaz2, Jorge Lopes3
1PhD Student of Faculty of Dental Medicine of University of Porto.
Background:
In orthodontic treatment, the combination of an activator with a headgear is commonly used in treatment of the hyperdivergent Class II malocclusion. However, the distribution of stresses transmitted to the maxilla by these appliances has been little studied. This study aimed to compare the biomechanical effects of stresses transmitted to the maxilla and teeth by a Teuscher activator (TA) for different lines of action of extraoral force, using finite element analysis.
Material And Methods:
A tridimensional finite element model of the maxilla and teeth was created based on the true geometry of a human skull. The (TA) and the face bow were designed in 3D computer-aided design and fixed in the maxilla model. To study the effects of mechanical stress transmitted to the maxilla in the treatment of hyperdivergent Class II malocclusion with (TA) combined with extraoral forces, five different finite element models were used, considering the centers of resistance of the maxilla and dentition.
Results:
The results showed that stresses increased progressively when the force line of action moved in posteroanterior direction. Von Mises equivalent stress was lower in Model 1 (0°) than in Model 5 (60°). In Models 1 (0°) and 2 (15°), molars suffered greater distal displacement and incisors showed extrusion. In Model 3 (30°), the force line of action promoted a distal displacement of molars and incisors. In Models 4 (45°) and 5 (60°), the whole maxillary anterior sector showed counterclockwise displacement.
Conclusions:
Different force lines of action influence the intensity and distribution of orthodontic and orthopedic forces in the maxilla. The extraoral force's line of action used in Model 3 (30°) is the most compatible with the objectives of the hyperdivergent Class II malocclusion treatment in growing patients. Key words:Class II, Headgear, Early treatment, FEA.
Related Concept Videos
Eccentric Axial Loading in a Plane of Symmetry
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...