On the Non-Adaptive Zero-Error Capacity of the Discrete Memoryless Two-Way Channel

Yujie Gu1, Ofer Shayevitz2

  • 1Faculty of Information Science and Electrical Engineering, Kyushu University, Fukuoka 819-0395, Japan.

Related Concept Videos

Lossless Lines01:23

Lossless Lines

In electrical engineering, a lossless transmission line is characterized by a purely imaginary propagation constant and a resistive characteristic impedance. The ABCD parameters, which describe the relationship between the input and output voltages and currents, indicate an equivalent π circuit with an imaginary series impedance and a shunt admittance. This results in a transmission line that, when the product of the phase constant (beta) and the length of the line is less than pi,...
191
Boundary Conditions: Lossless Lines01:21

Boundary Conditions: Lossless Lines

Consider a single-phase, two-wire, lossless transmission line terminated by an impedance at the receiving end and a source with Thevenin voltage and impedance at the sending end. The line, with length, has a surge impedance and wave velocity determined by the line's inductance and capacitance.
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
172
Equivalent Capacitance01:19

Equivalent Capacitance

Multiple capacitors can be connected in a circuit in series or parallel configuration. When the capacitor combination is connected to a battery, the potential drop across each capacitor and the magnitude of charge stored in the individual capacitor depends on the type of the connection. The capacitor combination is replaced by a single equivalent capacitor that stores the same amount of charge as the combination for a given potential difference.
The following strategies are adopted to calculate...
1.7K
Propagation of Uncertainty from Random Error00:59

Propagation of Uncertainty from Random Error

An experiment often consists of more than a single step. In this case, measurements at each step give rise to uncertainty. Because the measurements occur in successive steps, the uncertainty in one step necessarily contributes to that in the subsequent step. As we perform statistical analysis on these types of experiments, we must learn to account for the propagation of uncertainty from one step to the next. The propagation of uncertainty depends on the type of arithmetic operation performed on...
1.2K
MOS Capacitor01:25

MOS Capacitor

A Metal-Oxide-Semiconductor (MOS) capacitor is a fundamental structure used extensively in semiconductor device technology, particularly in the fabrication of integrated circuits and MOSFETs (metal-oxide-semiconductor field-effect transistors). The MOS capacitor consists of three layers: a metal gate, a dielectric oxide, and a semiconductor substrate.
The metal gate is typically made from highly conductive materials such as aluminum or polysilicon. Beneath the metal gate lies a thin layer of...
1.1K
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model01:13

Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model

Drugs administered through various routes can lead to nonlinear elimination, resulting in complex pharmacokinetic behaviors crucial to understanding efficacious drug dosing.
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
140