X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Effectiveness of a Real-Time X-ray Dosimetry Monitor in Reducing Radiation Exposure in Coronary Procedures: The
Maximilian Olschewski1, Helen Ullrich1, Moritz Brandt1
1Department of Cardiology, Cardiology 1, University Medical Center Mainz and Deutsches Zentrum für Herz und Kreislauf Forschung, Standort Rhein-Main, 55131 Mainz, Germany.
Abstract:
Background-Several methods to reduce radiation exposure in the setting of coronary procedures are available on the market, and we previously showed that additional radiation shields reduce operator exposure during radial interventions. We set out to examine the efficacy of real-time personal dosimetry monitoring in a real-world setting of radial artery catheterization. Methods and Results-In an all-comer prospective, parallel study, consecutive coronary diagnostic and intervention procedures were performed with the use of standard radiation shield alone (control group) or with the addition of a real-time dosimetry monitoring system (Raysafe, Billdal, Sweden, monitoring group). The primary outcome was the difference in exposure of the primary operator among groups. Additional endpoints included patient, nurse, second operator exposure and fluoroscopy time. A total of 700 procedures were included in the analysis (n = 369 in the monitoring group). There were no differences among groups in patients' body mass index (p = 0.232), type of procedure (intervention vs. diagnostic, p = 0.172), and patient sex (p = 0.784). Fluoroscopy time was shorter in the monitoring group (5.6 (5.1-6.2) min vs. 7.0 (6.1-7.7) min, p = 0.023). Radiation exposure was significantly lower in the monitoring group for the patient (135 (115-151) µSv vs. 208 (176-245) µSv, p < 0.0001) but not for the first operator (9 (7-11) µSv vs. 10 (8-11), p = 0.70) and the assistant (2 (1-2) µSv vs. 2 (1-2) µSv, p = 0.121). Conclusions-In clinical daily practice, the use of a real-time dosimetry monitoring device reduces patient radiation exposure and fluoroscopy time without an effect on operator radiation exposure.
More Related Videos
11:38Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
X-ray Imaging
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT