Related Experiment Video
Updated: Oct 11, 2025

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Digital analysis of external fixation area of proximal humerus fractures in elderly patients
Baorui Xing1, Yadi Zhang2, Xiuxiu Hou1
1Cangzhou Hospital of integrated traditional Chinese medicine and Western medicine, No.31, West Huanghe Road, Yunhe District, Cangzhou, 061000, Hebei Province, China.
Introduction:
The purpose is based on anatomical basis, combined with three-dimensional measurement, to guide the clinical repositioning of proximal humeral fractures, select the appropriate pin entry point and angle, and simulate surgery.
Methods:
11 fresh cadaveric specimens were collected, the distance of the marked points around the shoulder joint was measured anatomically, and the vertical distance between the inferior border of the acromion and the superior border of the axillary nerve, the vertical distance between the apex of the humeral head and the superior border of the axillary nerve, the vertical distance between the inferior border of the acromion and the superior border of the anterior rotator humeral artery, and the vertical distance between the apex of the humeral head and the superior border of the anterior rotator humeral artery were marked on the 3D model based on the anatomical data to find the relative safety zone for pin placement.
Results:
Contralateral data can be used to guide the repositioning and fixation of that side of the proximal humerus fracture, and uniform data cannot be used between male and female patients. For lateral pining, the distance of the inferior border of the acromion from the axillary nerve (5.90 ± 0.43) cm, range (5.3-6.9) cm, was selected for pining along the medial axis of the humeral head, close to the medial cervical cortex, and the pining angle was measured in the coronal plane (42.84 ± 2.45)°, range (37.02° ~ 46.31°), and in the sagittal plane (28.24 ± 2.25)°, range (19.22° ~ 28.51°). The pin was advanced laterally in front of the same level of the lateral approach point to form a cross-fixed support with the lateral pin, and the pin angle was measured in the coronal plane (36.14 ± 1.75)°, range (30.32° ~ 39.61°), and in the sagittal plane (28.64 ± 1.37)°, range (22.82° ~ 32.11°). Two pins were taken at the greater humeral tuberosity for fixation, with the proximal pin at an angle (159.26 ± 1.98) to the coronal surface of the humeral stem, range (155.79° ~ 165.08°), and the sagittal angle (161.76 ± 2.15)°, with the pin end between the superior surface of the humeral talus and the inferior surface of the humeral talus. The distal needle of the greater humeral tuberosity was parallel to the proximal approach trajectory, and the needle end was on the inferior surface of the humeral talus.
Conclusion:
Based on the anatomical data, we can accurately identify the corresponding bony structures of the proximal humerus and mark the location of the pin on the 3D model for pin placement, which is simple and practical to meet the relevant individual parameters.
More Related Videos
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Humerus