Related Experiment Video
Updated: Oct 11, 2025

Assessment of Audio-Tactile Sensory Substitution Training in Participants with Profound Deafness Using the Event-Related Potential Technique
Published on: September 7, 2022
Audiometric Characteristics and Tinnitus Features in a Cohort of 170 Spanish Patients
1Institute of Physical and Information Technologies (ITEFI), Spanish National Research Council (CSIC), Serrano 144, 28006 Madrid, Spain.
Background:
Tinnitus is a rather prevalent, quite heterogeneous, and difficult to treat auditory disorder. The aim of this article is to provide the design and results of a cross-sectional study related to audiological and tinnitus features in a group of 170 Spanish patients.
Methods:
Audiometric characteristics were assessed on the basis of the pure-tone audiometry of both ears in 170 tinnitus patients and 85 control subjects. The audiometric status of each tinnitus participant was assessed on the basis of the average auditory threshold (AAT) in the whole frequency range (from 125 Hz to 8 kHz), and low (from 125 Hz to 2 kHz) and high (from 3 kHz to 8 kHz)-frequency intervals. Tinnitus features were evaluated through personal interview with patients and included tinnitus duration, laterality, pitch, sound, and distress (Tinnitus Handicap Inventory, THI). Correlational analysis was carried out between audiological (AAT) and tinnitus (THI) variables.
Results:
A very weak Spearman rank correlation factor is found between both variables.
Conclusions:
The subjective outcome of tinnitus distress (THI) was not correlated with the objective measure of hearing loss (AAT) in our cohort.