Detection, detoxification, and removal of multiply heavy metal ions using a recyclable probe enabled by click and
Yifei Guo1, Yuanqiang Sun1, Zhaohui Li1
1College of Chemistry, Green Catalysis Center, Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Zhengzhou University, Zhengzhou 450001, PR China.
Abstract:
The pollution of water with heavy metal ions has generated great concern among both the public and academics due to the high toxicity, persistence, and non-degradability of heavy metals. The detection, detoxification, and removal of heavy metal ions are critical for monitoring water quality and treating polluted water. However, these tasks remain challenging due to lack of effective detection, detoxification, and removal strategies. By combining thiol-triggered click chemistry and heavy metal ion-triggered declick chemistry, a recyclable fluorescent probe for detecting numerous heavy metal ions was successfully developed through simple addition of thiol-containing heavy metal antidote to a carefully selected Michael acceptor-type fluorophore. The probe could be regenerated by adding equal amount of antidote to the detection solution without any purification step recycled up to 10 times. The generated water-soluble heavy metal ion-antidote complexes showed weak toxicity to biological systems, indicating successful detoxification. Finally, a simple, economical, and practical device for detecting, detoxifying, and removing heavy metal ions was fabricated by loading the recyclable fluorescent probe into polymer beads. The percent of detection, and removal are 98.10% and 97.59%, respectively. And detoxification percent is as high as 65.55%. The device is a promising candidate for water quality monitoring and treatment.
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Electrodeposition
Electrodeposition can...
Extraction: Advanced Methods
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Ion-Exchange Chromatography