Related Experiment Video
Updated: Oct 11, 2025

Author Spotlight: An Economic and Efficient Method for Quantitative Evaluation of Bone Microarchitecture in a Murine Osteoporosis Model
Published on: September 8, 2023
Characterization of bone remodeling of two different porous types of β-tricalcium phosphates: a quantitative
Naoya Kikuchi1, Tomokazu Yoshioka2,3, Kosuke Okuno4
1Department of Orthopedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan. nhskikuchi@md.tsukuba.ac.jp.
Abstract:
This study compared the process of bone remodeling using spherical porous β-tricalcium phosphate (SPTCP) and unidirectional porous β-tricalcium phosphate (UDPTCP) by quantitative computed tomography (CT) analysis. We retrospectively analyzed the data of 16 patients (4 men, 12 women; age, 43-78 years) who underwent medial opening wedge high tibial osteotomy (MOWHTO) and were followed up for 1 year postoperatively. Nine patients used SPTCP spacers and seven patients used UDPTCP spacers. CT was performed at 1 week, 6 months, and 1 year postoperatively. CT attenuation values were measured at three sites on the axial slice and sagittal slice, i.e., the superior, center, and inferior sites and the lateral, center, and medial sites for UDPTCP and SPTCP, respectively. CT attenuation values were lower for UDPTCP than for SPTCP in all sites at 6 months and 1 year postoperatively (p < 0.05). CT attenuation values decreased in the superior and inferior sites for UDPTCP (p < 0.05), and CT attenuation values decreased in the lateral site for both SPTCP and UDPTCP (p < 0.05). The process of bone remodeling differed between the two over a short-term follow-up of 1 year postoperatively.