Background:
Left ventricular hypertrophy detected by echocardiography (Echo-LVH) is an independent predictor of mortality. Integration of the Philips DXL-16 algorithm into the electrocardiogram (ECG) extensively analyses the electricity of the heart. Machine learning techniques such as the C5.0 could lead to a new decision tree criterion to detect Echo-LVH.
Objectives:
To search for a new combination of ECG parameters predictive of Echo-LVH. The final model is called the Cardiac Hypertrophy Computer-based model (CHCM).
Methods:
We extracted the 458 ECG parameters provided by the Philips DXL-16 algorithm in patients with Echo-LVH and controls. We used the C5.0 ML algorithm to train, test, and validate the CHCM. We compared its diagnostic performance to validate state-of-the-art criteria in our patient cohort.
Results:
We included 439 patients and considered an alpha value of 0.05 and a power of 99%. The CHCM includes T voltage in I (≤0.055 mV), peak-to-peak QRS distance in aVL (>1.235 mV), and peak-to-peak QRS distance in aVF (>0.178 mV). The CHCM had an accuracy of 70.5% (CI95%, 65.2-75.5), a sensitivity of 74.3%, and a specificity of 68.7%. In the external validation cohort (n = 156), the CHCM had an accuracy of 63.5% (CI95%, 55.4-71), a sensitivity of 42%, and a specificity of 82.9%. The accuracies of the most relevant state-of-the-art criteria were: Romhilt-Estes (57.4%, CI95% 49-65.5), VDP Cornell (55.7%, CI95%47.6-63.7), Cornell (59%, CI95%50.8-66.8), Dalfó (62.9%, CI95%54.7-70.6), Sokolow Lyon (53.9%, CI95%45.7-61.9), and Philips DXL-16 algorithm (54.5%, CI95%46.3-62.5).
Conclusion:
ECG computer-based data and the C5.0 determined a new set of ECG parameters to predict Echo-LVH. The CHCM classifies patients as Echo-LVH with repolarization abnormalities or LVH with increased voltage. The CHCM has a similar accuracy, and is slightly more sensitive than the state-of-the-art criteria.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...