Q waves are the strongest electrocardiographic variable associated with primary prophylactic implantable
Ari Pelli1, M Juhani Junttila1,2, Tuomas V Kenttä1
1Research Unit of Internal Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, PO Box 5000, FIN-90014 Oulu, Finland.
Aim:
The association of standard 12-lead electrocardiogram (ECG) markers with benefits of the primary prophylactic implantable cardioverter-defibrillator (ICD) has not been determined in the contemporary era. We analysed traditional and novel ECG variables in a large prospective, controlled primary prophylactic ICD population to assess the predictive value of ECG in terms of ICD benefit.
Methods And Results:
Electrocardiograms from 1477 ICD patients and 700 control patients (EU-CERT-ICD; non-randomized, controlled, prospective multicentre study; ClinicalTrials.gov Identifier: NCT02064192), who met ICD implantation criteria but did not receive the device, were analysed. The primary outcome was all-cause mortality. In ICD patients, the co-primary outcome of first appropriate shock was used. Mean follow-up time was 2.4 ± 1.1 years to death and 2.3 ± 1.2 years to the first appropriate shock. Pathological Q waves were associated with decreased mortality in ICD patients [hazard ratio (HR) 0.54, 95% confidence interval (CI) 0.35-0.84; P < 0.01] and patients with pathological Q waves had significantly more benefit from ICD (HR 0.44, 95% CI 0.21-0.93; P = 0.03). QTc interval increase taken as a continuous variable was associated with both mortality and appropriate shock incidence, but commonly used cut-off values, were not statistically significantly associated with either of the outcomes.
Conclusion:
Pathological Q waves were a strong ECG predictor of ICD benefit in primary prophylactic ICD patients. Excess mortality among Q wave patients seems to be due to arrhythmic death which can be prevented by ICD.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Acute Coronary Syndrome III: Diagnostic Studies
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias