Anticoagulation in syncardia total artificial heart recipients: anti-factor Xa or activated partial thromboplastin
María Monteagudo-Vela1, Christopher Bowles1, Binu Raj1
1Department of Cardiothoracic Transplantation and Mechanical Circulatory Support, Harefield Hospital, Guys and St Thomas' NHS Foundation Trust, London, UK.
Although the activated partial thromboplastin time (aPTT) has historically been the method of choice for anticoagulation monitoring in patients undergoing mechanical circulatory support with intravenous unfractionated heparin, it is being progressively superseded by the anti-factor Xa (anti-Xa) method. A retrospective single-arm, single-centre analysis of 20 patients who underwent total artificial heart implantation entailed simultaneous determinations of aPTT and anti-Xa. Agreement between these parameters was assessed using the Bland-Altman method. Despite a positive correlation between aPTT and anti-Xa, normal target ranges were poorly aligned: from 5th to 30th postoperative day, for anti-Xa values of 0.2 and 0.4 U/ml corresponding aPTT values were 52.1 and 65.2 s, 7.9 and 14.8 lower than predicted values, respectively. This was not associated with thromboembolic sequalae. It was not possible to demonstrate a significant relationship between the predictor variables (postoperative day; white blood cell count; C-reactive protein concentration; alanine transaminase and alkaline phosphatase level; bilirubin; haemoglobin; albumin and total protein concentration) and the agreement between aPTT and anti-Xa levels. In summary, when anti-Xa levels were used to guide anticoagulation therapy, corresponding aPTT levels were low with respect to target range. Methodology applied in this study is generalizable to other forms of mechanical circulatory support.
Although the activated partial thromboplastin time (aPTT) has historically been the method of choice for anticoagulation monitoring in patients undergoing mechanical circulatory support with intravenous unfractionated heparin, it is being progressively superseded by the anti-factor Xa (anti-Xa) method. A retrospective single-arm, single-centre analysis of 20 patients who underwent total artificial heart implantation entailed simultaneous determinations of aPTT and anti-Xa. Agreement between these parameters was assessed using the Bland-Altman method. Despite a positive correlation between aPTT and anti-Xa, normal target ranges were poorly aligned: from 5th to 30th postoperative day, for anti-Xa values of 0.2 and 0.4 U/ml corresponding aPTT values were 52.1 and 65.2 s, 7.9 and 14.8 lower than predicted values, respectively. This was not associated with thromboembolic sequalae. It was not possible to demonstrate a significant relationship between the predictor variables (postoperative day; white blood cell count; C-reactive protein concentration; alanine transaminase and alkaline phosphatase level; bilirubin; haemoglobin; albumin and total protein concentration) and the agreement between aPTT and anti-Xa levels. In summary, when anti-Xa levels were used to guide anticoagulation therapy, corresponding aPTT levels were low with respect to target range. Methodology applied in this study is generalizable to other forms of mechanical circulatory support.
Related Concept Videos
Venous Thrombosis III: Interprofessional Care
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...