Objective:
This study was conducted to investigate the clinical utility of quantitative bone single-photon computed tomography-computed tomography (SPECT/CT) for detection and classification for medication-related osteonecrosis of the jaw (MRONJ).
Materials And Methods:
Fifty-nine patients (69 lesions) clinically diagnosed as MRONJ by four specialists of Japanese Society of Oral Surgery according to the AAOMS diagnostic criteria and who underwent bone SPECT/CT were enrolled. One reader determined standard uptake values (SUVs), including maximum (SUVmax), peak (SUVpeak), and mean (SUVmean), as well as metabolic bone volume (MBV), representing total volume above threshold, and total bone uptake (TBU), calculated as MBV × SUVmean, using the GI-BONE software package. One-way repeated-measures analysis of variance and subsequent post hoc analysis were employed to compare quantitative values between clinical stages. To check reproducibility of values, another reader calculated these quantitative values.
Results:
Mean SUVmax values for stage 0 (n = 21), 1 (n = 13), 2 (n = 25), and 3 (n = 10) were 5.82 ± 3.20, 5.46 ± 3.79, 8.16 ± 3.93, and 10.57 ± 8.43, respectively, while values for MBV were 9.52 ± 6.33, 11.36 ± 7.32, 12.4 ± 8.21, and 17.84 ± 16.94, respectively, and for TBU were 40.60 ± 46.97, 53.70 ± 77.26, 62.37 ± 42.91, and 102.01 ± 74.52, respectively. There were significant differences for SUVmax, SUVpeak, and SUVmean between clinical stages (p = 0.024, p = 0.027, p = 0.039, respectively). Subsequent post hoc analysis showed that SUVmax and SUVpeak of stage 3 were significantly higher than those of stage 0 (p = 0.046, 0.045, respectively). MBV and TBU showed a tendency to increase with increased stage, though differences between stages were not significant (p = 0.15, p = 0.053, respectively). Little differences of mean SUVmax, SUVpeak, SUVmean, MBV, and TBU between two readers were observed (- 3.10%, - 0.26%, - 4.24%%, 0.69%, and - 3.42%, respectively). The intraclass correlation coefficients (ICCs) of SUVmax, SUVpeak, SUVmean, MBV, and TBU were 0.985, 0.990, 0.980, 0.994, and 0.994, respectively (almost perfect for all values).
Conclusion:
As objective and reliable indicators, SUVmax and SUVpeak derived from quantitative bone SPECT/CT results are useful for detection of early status disease, as well as staging in MRONJ patients.