Related Experiment Video
Updated: Oct 11, 2025

Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
Medially positioned plate in first metatarsophalangeal joint arthrodesis
Wojciech Witkowski1, Leszek Kuik2, Magdalena Rucka1
1Department of Mechanics of Materials and Structures, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland.
Objective:
The purpose of this study was to biomechanically compare the stability of first metatarsophalangeal (MTP1) joint arthrodesis with dorsally and medially positioned plates.
Methods:
A physical model of the MTP1 joint consists of printed synthetic bones, a titanium locking plate and screws. In the experiments, samples with dorsally and medially positioned plates were subjected to loading of ground load character in a universal testing machine. Force-displacement relations and relative displacements of bones were recorded. The obtained results were used to validate the corresponding finite element models of the MTP1 joint. Nonlinear finite element simulations of the toe-off phase of gait were performed to determine the deformation and stress state in the MTP1 joint for two positions of the plate.
Results:
In numerical simulations, the maximum displacement in the dorsal direction was noticed at the tip of the distal phalanx and was equal to 19.6 mm for the dorsal plate and 9.63 mm for the medial plate for a resultant force of 150 N. Lower relative bone displacements and smaller plastic deformation in the plate were observed in the model with the medial plate. Stress values were also smaller in the medially positioned plate and locking screws compared to fixation with the dorsal plate.
Conclusions:
A medially positioned locking plate provides better stability of the MTP1 joint than a dorsally positioned plate due to greater vertical bending stiffness of the medial plate. Smaller relative bone displacements observed in fixation with the medial plate may be beneficial for the bone healing process. Moreover, lower stress values may decrease the risk of complications associated with hardware failure.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024