Related Experiment Video
Updated: Oct 11, 2025

Veno-Venous Extracorporeal Membrane Oxygenation in a Mouse
Published on: October 24, 2018
Agreement Between the TEG 6s and TEG 5000 Analyzers in Extracorporeal Membrane Oxygenation
Abhimanyu Chandel1, Mehul Desai2, Christopher S King3
1Department of Pulmonology and Critical Care, Walter Reed National Military Medical Center, Bethesda, Maryland.
Abstract:
Thromboelastography (TEG) evaluates viscoelastic properties of blood clot formation. The TEG 5000 analyzer is commonly used but prone to errors related to vibration or operator error. The TEG 6s was developed to overcome these limitations. Performance of TEG 6s compared with TEG 5000 has not been reported in extracorporeal membrane oxygenation (ECMO). We compared the agreement between devices via a single-center prospective observational study in hospitalized adult patients on ECMO. Data for both devices were collected daily for 3 days after ECMO initiation. Standard tests for method comparison were used. Thirty-four matching samples were available for analysis. Minimal bias was noted; however, the limit of agreement was wide for TEG parameters. Visually, agreement was better for values within the reference ranges of the tests. Lin's coefficients demonstrated moderate correlation for reaction time and alpha angle (0.58; 95% confidence interval [CI], 0.31-0.76 and 0.63; 95% CI, 0.40-0.78, respectively). Excellent correlation was demonstrated for kinetic time and maximum amplitude (0.88; 95% CI, 0.79-0.94 and 0.89; 95% CI, 0.79-0.94). The TEG 6s device may represent an acceptable surrogate for the TEG 5000 in patients on ECMO. However, limitations in reliability were noted, and the devices may not be interchangeable when results fall outside of the reference values.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration