Accuracy of single intravenous access iohexol GFR in children is hampered by marker contamination

Thea Tislevoll Eide1, Karl Ove Hufthammer2, Atle Brun3,4

  • 1Renal Research Group, Department of Clinical Medicine, University of Bergen, Bergen, Norway.

Scientific Reports
|December 2, 2021
PubMed

Insights

Using a single IV line for iohexol injection and blood draws to measure glomerular filtration rate (GFR) in children is not accurate. Blood samples from the injection site may lead to falsely low GFR results, recommending a second IV line.

Area of Science:

  • Pediatric Nephrology
  • Diagnostic Imaging
  • Pharmacokinetics

Background:

  • Glomerular filtration rate (GFR) measurement in children is crucial for diagnosing and managing kidney disease.
  • Iohexol plasma clearance is a standard method for GFR assessment in pediatric populations.
  • A single intravenous (IV) access for both iohexol administration and blood sampling could simplify the procedure, reducing patient discomfort.

Purpose of the Study:

  • To evaluate the feasibility and accuracy of iohexol GFR (iGFR) measurements using blood samples drawn from the same IV access used for iohexol injection.

Main Methods:

  • Thirty-one children with chronic kidney disease underwent iGFR measurement using iohexol.
  • Paired blood samples were collected from the injection site and a contralateral arm (reference) at 2, 3, 3.5, and 4 hours post-injection.
  • Procedures included discarding initial blood samples and saline flushing to minimize marker contamination.

Main Results:

  • iGFR calculated from samples at 2 and 3 hours from the injection site was significantly lower than the reference method (p < 0.01).
  • No significant difference in single-point iGFR was observed at 3.5 and 4 hours after multiple blood discarding and flushing procedures.
  • Falsely low iGFR results due to marker contamination from the injection site remain a risk despite flushing.

Conclusions:

  • Drawing blood samples from the iohexol injection site for iGFR measurements in children is not recommended due to the risk of inaccurate, falsely low results.
  • A second, separate intravenous access is advised for routine iohexol GFR measurements in pediatric patients to ensure accuracy.