Related Experiment Video
Updated: Oct 11, 2025

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Accuracy of single intravenous access iohexol GFR in children is hampered by marker contamination
Thea Tislevoll Eide1, Karl Ove Hufthammer2, Atle Brun3,4
1Renal Research Group, Department of Clinical Medicine, University of Bergen, Bergen, Norway.
Insights
Using a single IV line for iohexol injection and blood draws to measure glomerular filtration rate (GFR) in children is not accurate. Blood samples from the injection site may lead to falsely low GFR results, recommending a second IV line.
Area of Science:
- Pediatric Nephrology
- Diagnostic Imaging
- Pharmacokinetics
Background:
- Glomerular filtration rate (GFR) measurement in children is crucial for diagnosing and managing kidney disease.
- Iohexol plasma clearance is a standard method for GFR assessment in pediatric populations.
- A single intravenous (IV) access for both iohexol administration and blood sampling could simplify the procedure, reducing patient discomfort.
Purpose of the Study:
- To evaluate the feasibility and accuracy of iohexol GFR (iGFR) measurements using blood samples drawn from the same IV access used for iohexol injection.
Main Methods:
- Thirty-one children with chronic kidney disease underwent iGFR measurement using iohexol.
- Paired blood samples were collected from the injection site and a contralateral arm (reference) at 2, 3, 3.5, and 4 hours post-injection.
- Procedures included discarding initial blood samples and saline flushing to minimize marker contamination.
Main Results:
- iGFR calculated from samples at 2 and 3 hours from the injection site was significantly lower than the reference method (p < 0.01).
- No significant difference in single-point iGFR was observed at 3.5 and 4 hours after multiple blood discarding and flushing procedures.
- Falsely low iGFR results due to marker contamination from the injection site remain a risk despite flushing.
Conclusions:
- Drawing blood samples from the iohexol injection site for iGFR measurements in children is not recommended due to the risk of inaccurate, falsely low results.
- A second, separate intravenous access is advised for routine iohexol GFR measurements in pediatric patients to ensure accuracy.
Abstract:
Measurement of glomerular filtration rate (GFR) in children by iohexol injection and blood sampling from the contralateral arm is widely used. A single intravenous access for iohexol injection and subsequent blood sampling has the obvious advantages of being less painful and easier to perform. The purpose of our study was to determine if blood samples drawn from the injection access are feasible and accurate for iohexol GFR (iGFR) measurements. Thirty-one children, median age 10.5 (range 6-17) years, with chronic kidney disease were given a bolus of iohexol followed by extended saline flushing and subsequent venous blood samples collected from the injection access as well as from a cannula in the contralateral arm, the latter serving as the reference method. Paired venous blood samples were collected at four time points (2, 3, 3.5 and 4 h) after the iohexol bolus. Blood sample discarding preceded and saline flushing followed each blood sampling to avoid marker contamination. iGFR based on samples drawn from the injection access at 2 and 3 h showed significantly lower iGFR than measurement from the contralateral arm (p < 0.01). Singlepoint iGFR did not differ significantly after 3-4 repeated procedures of blood discarding and saline flusing (3.5 and 4 h). Despite thorough saline flushing there is still a relatively high risk of falsely low iGFR due to marker contamination in blood samples from the injection site. Hence, blood sampling from a second intravenous access is recommended for routine iohexol GFR measurements in children.Clinical trial registration: ClinicalTrials.gov, Identifier NCT01092260, https://clinicaltrials.gov/ct2/show/NCT01092260?term=tondel&rank=2 .
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration