Emission Spectroscopic Boundary Layer Investigation during Ablative Material Testing in Plasmatron
Published on: June 9, 2016
Multi-internal standard calibration applied to inductively coupled plasma optical emission spectrometry
John T Sloop1, George L Donati1, Bradley T Jones1
1Department of Chemistry, Wake Forest University, Salem Hall, Box 7486, Winston-Salem, NC, 27109, United States.
Abstract:
Several species are simultaneously used for internal standardization to improve accuracy in inductively coupled plasma optical emission spectrometry (ICP-OES). In multi-internal standard calibration (MISC), signal ratios between the analyte and each of several internal standard species are used for calibration. A single calibration solution is required, and the MISC graph is built with intensity ratios calculated with analytical signals recorded for the sample (IA,sam) on the y-axis, while those recorded for the calibration standard (IA,std) are plot on the x-axis (i.e. IA,sam/IIS(i)vs. IA,std/IIS(i), where IIS(i) represents the signal intensity for a given internal standard species). Nine analytes (As, Cd, Cr, Cu, Fe, Mg, Mn, Pb and Zn), and two sets of internal standard species (i.e. Bi, Ge, In, Rh, Sc, Te, Tl and Y in solution, or eighteen emission lines from plasma naturally occurring Ar) were evaluated in this proof-of-concept study. The MISC method's efficiency was evaluated by analyte addition and recovery experiments and by analyzing two certified reference materials. Figures of merit for MISC (limit of detection, repeatability and trueness) were comparable to those obtained for the traditional external standard calibration (EC) and internal standard (IS) methods. Different from IS, MISC requires no time-consuming study to identify an ideal internal standard species, and signal biases are minimized by an averaged, more encompassing internal standardization effect.
More Related Videos
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences