Related Experiment Video
Updated: Oct 11, 2025

Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Interobserver and Intra-Observer Reliability of Eyelid Tests for Ocular Myasthenia Gravis
Thanchat Jienmaneechotchai1, Supanut Apinyawasisuk, Supharat Jariyakosol
1Ophthalmology Department (TJ, SA, SJ, PH), King Chulalongkorn Memorial Hospital, Bangkok, Thailand; and Department of Ophthalmology (TJ, SA, SJ, PH), Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
Background:
Lid fatigability test (LFT), Cogan lid twitch (CLT), and forced eyelids closure test (FECT) are simple clinical screening tests for ocular myasthenia gravis (OMG). However, these tests are subjectively interpreted. We thus evaluated the interobserver and intra-observer reliability of each test.
Methods:
The 3 eyelid tests were performed in ptotic patients associated with various conditions, including OMG and others. Video clips of all tests were recorded using smartphone with built-in camera in the following order; LFT, CLT, and FECT. All video clips were distributed to 3 neuro-ophthalmologists and 3 general ophthalmologists, who were trained to evaluate the tests using a single standard instruction. After 3 months, all video clips were re-organized for the second evaluation. Interobserver and intra-observer reliability were calculated using Cohens' Kappa coefficient and Fleiss Kappa statistic.
Results:
The 3 eyelid tests were performed and recorded in 35 patients, which included the diagnosis of OMG, levator muscle dehiscence, partial oculomotor nerve palsy, and Horner syndrome. CLT received moderate-to-substantial interobserver reliability in neuro-ophthalmologist group (Fleiss Kappa 0.77 [95% CI 0.60-0.94] and 0.66 [95% CI 0.46-0.85] in first and second evaluation respectively), but the results varied in general ophthalmologist group (Fleiss Kappa 0.58 [95% CI 0.37-0.79] and 0.54 [95% CI 0.33-0.76] in first and second evaluation respectively). FECT and LFT received lower interobserver reliability in both groups. CLT also received moderate-to-almost perfect intra-observer reliability in neuro-ophthalmologist group (Cohen Kappa 0.55, 0.58, and 0.92), whereas FECT and LFT received lower intra-observer reliability. The intra-observer reliability varied among general ophthalmologists for all 3 eyelid tests.
Conclusions:
CLT is the most reliable test among the 3 eyelid tests. However, all tests should be interpreted with caution by general ophthalmologists.
Related Concept Videos
Muscles of the Eye
Extraocular Muscles
The six extraocular muscles surround the eyeball and control its movements. They are responsible for a wide range of eye motions, including looking up, down, left, right, and...
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...
Accessory Structures of the Eye

