Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Development of a secondary standard ionization chamber for environmental level ambient dose equivalent measurement
1China Institute of Atomic Energy, Division of Radiation Metrology, Mailbox 275, Beijing, 102413, China.
Abstract:
Ambient dose equivalent is the calibration quantity and type inspection quantity of environmental and workplace radiation monitoring instrument. For other unknown radiation fields other than the reference radiation field, the method of directly measuring H*(10) by secondary standard is particularly important. In order to ensure the reliability and accuracy of the value transfer of H*(10), an energy compensated high pressure ionization chamber for environmental level measurement was developed and used as a secondary standard. Firstly, the conversion coefficients from air kerma to ambient dose equivalent of X and γ-ray reference radiation field were calculated by Monte Carlo simulation. Then, the Monte Carlo model of ionization chamber was established, the thickness and energy compensation scheme of the outer wall of the chamber high voltage electrode was determined. Finally, the performance of the chamber were studied according to the calculated conversion coefficients. The results indicate that the relative deviation between calculated conversion coefficients and recommended value of ISO 4037-3 in the range of 15 keV-1.5 MeV is within ±4%. The ionization chamber meets the energy response requirements of ISO 4037-2 in the range of 65 keV-1.25 MeV. The linearity range of ambient dose equivalent rate is 0.8 μSv/h∼11.9 mSv/h, which can be used for a directly measurement of environmental level H*(10).
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
09:46Production and Measurement of Organic Particulate Matter in the Harvard Environmental Chamber
Published on: November 18, 2018
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Instrumentation
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...