Related Experiment Video
Updated: Oct 11, 2025

Author Spotlight: Advancements in Impedance Monitoring for Cochlear Implant Surgery
Published on: August 4, 2023
Impedance planimetry (EndoFLIP) measurements persist long term after anti-reflux surgery
Hoover Wu1, Mikhail Attaar1, Harry J Wong1
1Department of Surgery, NorthShore University Health System, Evanston, IL; Department of Surgery, University of Chicago Medical Center, Chicago, IL.
Purpose:
The functional lumen imaging probe provides objective measurements of the gastroesophageal junction during laparoscopic anti-reflux surgery. There is a lack of data on how functional lumen imaging probe measurements change at follow-up. We aim to describe our institutional experience in performing functional lumen imaging probe during postoperative endoscopy after laparoscopic anti-reflux surgery.
Methods:
A prospectively maintained database was queried. Patients who had postoperative endoscopic functional lumen imaging probe measurements between March 2018 and June 2021 were assessed at different time points from their index laparoscopic anti-reflux surgery using paired t test. Standardized quality of life questionnaires were collected for up to 2 years. Group comparisons were made using the Wilcoxon rank-sum test.
Results:
Fifty-eight patients who underwent laparoscopic anti-reflux surgery (magnetic sphincter augmentation or fundoplication) had postoperative functional lumen imaging probe. Thirty-two intraoperative functional lumen imaging probe values were compared with their postoperative functional lumen imaging probe. Fundoplication values did not differ. Postoperative functional lumen imaging probe distensibility index for magnetic sphincter augmentation patients was decreased (P = .04). Functional lumen imaging probe measurements for all postoperative endoscopies showed that magnetic sphincter augmentation had the lowest distensibility index (P < .01). Dysphagia as a reason for endoscopy had a decrease in distensibility index (P = .03).
Conclusion:
Functional lumen imaging probe measurements after fundoplication persist at long-term follow up while patients may have a tighter gastroesophageal junction after magnetic sphincter augmentation. Functional lumen imaging probe has the potential to assess the success or failure after laparoscopic anti-reflux surgery and optimize patient outcomes.
More Related Videos
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
09:40An Ivor Lewis Esophagectomy Designed to Minimize Anastomotic Complications and Optimize Conduit Function
Published on: April 17, 2020
Related Concept Videos
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures V: ERCP
Patient...