The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Comparison of tracheal intubation between sitting position and standing position in COVID-19 patients: A manikin
Yong Wang1,2, Yun Shi3, Yong-Xing Li1
1Department of Anesthesiology, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China.
Abstract:
It is recommended to use visual laryngoscope for tracheal intubation in a Corona Virus Disease 2019 patient to keep the operator farther from the patient. How the position of the operator affects the distance in this setting is not ascertained. This manikin study compares the distances between the operator and the model and the intubation conditions when the operator is in sitting position and standing position, respectively.Thirty one anesthesiologists with minimum 3-years' work experiences participated in the study. The participant's posture was photographed when he performed tracheal intubation using UE visual laryngoscope in standing and sitting position, respectively. The shortest distance between the model's upper central incisor and operator's face screen (UF), the horizontal distance between the model's upper central incisor and the operator's face screen, the angle between the UF line and the vertical line of the model's upper central incisor were measured. The success rate of intubation, the duration of intubation procedure, the first-attempt success rate, the Cormack-Lehane grade, and operator comfort score were also recorded.When the operator performed the procedure in sitting position, the horizontal distance between the model's upper central incisor and the operator's face screen distance was significantly longer (9.5 [0.0-17.2] vs 24.3 [10.3-33.0], P ≤ .001) and the angle between the UF line and the vertical line of the model's upper central incisor angle was significantly larger (45.2 [16.3-75.5] vs 17.7 [0.0-38.9], P ≤ .001). There was no significant difference in UF distance when the operator changed the position. Cormack-Lehane grade was significantly improved when it was assessed using visual laryngoscope. Cormack-Lehane grade was not significantly different when the operator assessed it in sitting and standing position, respectively. No significant differences were found in the success rate, duration for intubation, first-attempt success rate, and operator comfort score.The operator is kept farther from the patient when he performs intubation procedure in sitting position. Meanwhile, it does not make the procedure more difficult or uncomfortable for the operator, though all the participants prefer to standing position.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Tracheostomy Suctioning II: Procedure