Related Experiment Video
Updated: Oct 11, 2025

An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
Published on: May 26, 2020
Foot angular kinematics measured with inertial measurement units: A reliable criterion for real-time gait event
Milad Nazarahari1, Aminreza Khandan1, Atif Khan1
1Department of Mechanical Engineering, University of Alberta, Donadeo Innovation Centre for Engineering, Edmonton, Alberta, T6G-1H9, Canada.
Abstract:
Accurate and reliable real-time detection of gait events using inertial measurement units (IMUs) is crucial for (1) developing clinically meaningful gait parameters to differentiate normal and impaired gait or (2) creating patient-tailored gait rehabilitation strategies or control of prosthetic devices using feedback from gait phases. However, most previous studies focused only on algorithms with high temporal accuracy and neglected the importance of (1) high reliability, i.e., detecting only and all true gait events, and (2) real-time implementation. Thus, in this study, we presented a novel approach for initial contact (IC) and terminal contact (TC) detection in real-time based on the measurement of the foot orientation. Unlike foot/shank angular velocity and acceleration, foot orientation provides physiologically meaningful kinematic features corresponding to our observational recognition of IC and TC, regardless of the walking modality. We conducted an experimental study to validate our algorithm, including seven participants performing four walking/running activities. By analyzing 5,555 ICs/TCs recorded during the tests, only our algorithm achieved a sensitivity and precision of 100%. Our obtained temporal accuracy (mean ± standard deviation of errors ranging from 0 ± 3 to 6 ± 5 time samples; sampling frequency: 100 Hz) was better than or comparable to those reported in the literature. Our algorithm's performance does not depend on thresholds and gait speed/modality, and it can be used for feedback-based therapeutic gait training or real-time control of assistive or prosthetic technologies. Nevertheless, its performance for pathological gait must be validated in the future. Finally, we shared the codes and sample data on https://www.ncbl.ualberta.ca/codes.
Related Concept Videos
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Angular Velocity and Acceleration

