Related Experiment Video
Updated: Oct 11, 2025

Spatial Measurements of Perfusion, Interstitial Fluid Pressure and Liposomes Accumulation in Solid Tumors
Published on: August 18, 2016
CT Texture analysis and CT scores for characterization of fluid collections
Hans-Jonas Meyer1, Benedikt Schnarkowski2, Jakob Leonhardi2
1Department of Diagnostic and Interventional Radiology, University of Leipzig, Liebigstraße 20, 04103, Leipzig, Germany. Hans-jonas.meyer@medizin.uni-leipzig.de.
Background:
Texture analysis derived from Computed tomography (CT) might be able to better characterize fluid collections undergoing CT-guided percutaneous drainage treatment. The present study tested, whether texture analysis can reflect microbiology results in fluid collections suspicious for septic focus.
Methods:
Overall, 320 patients with 402 fluid collections were included into this retrospective study. All fluid collections underwent CT-guided drainage treatment and were microbiologically evaluated. Clinically, serologically parameters and conventional imaging findings as well as textures features were included into the analysis. A new CT score was calculated based upon imaging features alone. Established CT scores were used as a reference standard.
Results:
The present score achieved a sensitivity of 0.78, a specificity of 0.69, area under curve (AUC 0.82). The present score and the score by Gnannt et al. (AUC 0.81) were both statistically better than the score by Radosa et al. (AUC 0.75). Several texture features were statistically significant between infected fluid collections and sterile fluid collections, but these features were not significantly better compared with conventional imaging findings.
Conclusions:
Texture analysis is not superior to conventional imaging findings for characterizing fluid collections. A novel score was calculated based upon imaging parameters alone with similar diagnostic accuracy compared to established scores using imaging and clinical features.
More Related Videos
12:39DUCT: Double Resin Casting followed by Micro-Computed Tomography for 3D Liver Analysis
Published on: September 28, 2021
09:00Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography
Published on: September 29, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Ultrasonography
During an ultrasonography procedure, a handheld device called...