Related Experiment Video
Updated: Oct 10, 2025

A Semi-Quantitative Drug Affinity Responsive Target Stability DARTS assay for studying Rapamycin/mTOR interaction
Published on: August 27, 2019
Simultaneous measurement of upadacitinib and methotrexate by UPLC-MS/MS and its pharmacokinetic application in rats
Junwei Li1, Chaojie Chen2, Jing Wang3
1School of Pharmaceutical Sciences, Wenzhou Medical University, Zhejiang, China.
Abstract:
Upadacitinib, as a selective and reversible Janus kinase (JAK) inhibitor, has been widely used in the treatment of atopic dermatitis, ulcerative colitis and other inflammatory bowel diseases and other immune-mediated diseases. The combination of methotrexate and upadacitinib is a common clinical treatment strategy for rheumatoid arthritis (RA) in recent years. In this study, we established an ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) assay for quantitative measurement of upadacitinib and methotrexate, by which we successfully determined pharmacokinetic parameters of them in rat plasma. In order to pretreat the samples, we used acetonitrile as the precipitant, and for the internal standard (IS), we chose tofacitinib. The Acquity BEHC18 (2.1 mm × 50 mm, 1.7 μm) column, with acetonitrile and 0.1% formic acid aqueous solution composed mobile phases, was used to separate upadacitinib, methotrexate and tofacitinib. A Xevo TQ-S triple quadrupole tandem mass spectrometer was used as the detecting instrument in the positive ion mode. For upadacitinib, excellent linearity was shown of this assay in the calibration range with 0.1-200 ng/mL, and as for methotrexate, the range was 0.05-100 ng/mL. As the results indicated, the lower limit of quantification (LLOQ) was respectively 0.1 and 0.05 ng/mL for upadacitinib and methotrexate, the intra- and inter-day precision were ≤ 13.3%, and the accuracy of all the analytes ranged from -4.1% to 12.7%. The recovery of each analyte was > 80.2% in this experiment, and matrix effects we observed were unobvious. The establishment of this method and its successful application in rat plasma can provide a theoretical and technical support for the deeper study of pharmacodynamics and the clinical medication strategies.
More Related Videos
08:57Sample Extraction and Simultaneous Chromatographic Quantitation of Doxorubicin and Mitomycin C Following Drug Combination Delivery in Nanoparticles to Tumor-bearing Mice
Published on: October 5, 2017
08:38Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
Published on: November 8, 2015
Related Concept Videos
Measurement of Bioavailability: Pharmacodynamic Methods
Measurement of Bioavailability: Pharmacokinetic Methods
Therapeutic Drug Monitoring: Drug Analysis Methods