Related Experiment Video
Updated: Oct 10, 2025

Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
A Method to Calculate the Support Length of Beams Resting on Masonry Walls
Marco Andrea Pisani1, Massimiliano Bocciarelli1, Tommaso D'Antino1
1Department of Architecture, Built Environment, and Construction Engineering, Politecnico di Milano, 20133 Milan, Italy.
Abstract:
Rehabilitation, strengthening, and retrofitting of existing masonry buildings represent an important challenge for the construction engineering field. Often, slab strengthening/retrofitting is performed by replacing existing timber and steel beams or by adding new beams to improve the slab load-carrying capacity. The computation of the stresses at the beam-masonry interface (i.e., the contact pressure) is crucial to properly design the beam support length, preventing local failure of masonry and beam. This paper presents a simple analytical procedure to compute the contact pressure at the beam-masonry interface. The analytical procedure is validated by comparison between analytical and corresponding numerical results obtained by finite element modeling. Different types of beam (solid and laminated timber beams and steel beams) were considered, as well as different support conditions (simply resting on the wall considering different support lengths or fully embedded). The results obtained show that the method proposed is simple and reliable, which makes it suitable for professional practice.
Related Concept Videos
Masonry Loadbearing Walls
Design Example: Dimensioning of Concrete Masonry Construction
The site engineer has laid out a plan for the storeroom with external dimensions of twelve feet in length and...
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...
Laying Concrete Masonry
Mortar application focuses on the face shells of the blocks, the sides that face outward,...
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.