Radiation Dose Modulation of Computed Tomography Component in Positron Emission Tomography/Computed Tomography
1Department of Diagnostic Radiology, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan.
Abstract:
In oncology practice, the CT component of PET/CT may be used for attenuation correction, lesion localization, and CT diagnosis, and significantly enhances the clinical benefit of PET. However, acquisition of CT covering the whole body increases radiation dose and consequently the risk of cancer induction, and optimization should be pursued. In CT, radiation dose is a major determinant of image quality, and is mainly adjusted by modulation of tube current. Automatic exposure control (AEC) is widely used for tube current modulation, and increases tube current in a large patient and in strongly attenuating regions of a given patient to preserve image quality despite strong X-ray attenuation. Radiation dose determined by AEC depends on various factors, such as the type of AEC software, scout imaging direction, arm positioning, and patient centering. Because radiation dose reduction increases image noise and may degrade clinical utility, image quality should be assessed together with radiation dose in the process of optimization. Clinical demands for image quality vary largely depending on the aim of the CT component, with lower quality being sufficient for lesion localization than for CT diagnosis. Therefore, optimal radiation dose differs according to the aim. Determining optimal dose is a somewhat subjective and difficult task, and use of the diagnostic reference level, determined based on national or regional survey, is recommended to recognize need for optimization. The volume CT dose index and dose-length product are used as indices of CT radiation dose, and effective dose may also be calculated for comparison of stochastic effects among different radiation sources and among different imaging procedures. Wide coverage from the head to the lower extremities causes problems in estimating these indices in whole-body PET/CT. CT definitely enhances clinical benefits of PET but simultaneously increases potential detriments due to radiation exposure. In the era of hybrid imaging, nuclear medicine practitioners should be aware of the technology and radiation dose management of CT.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET