Background And Aims:
The measurement of the portosystemic pressure gradient (PSG) in patients with advanced liver disease is helpful to assess the severity of portal hypertension (PH) and predict adverse clinical outcomes. EUS-guided PSG (EUS-PSG) measurement is a novel tool to assess PSG in all patients with advanced liver disease. We sought to assess the safety, feasibility, and technical success of simultaneous EUS-PSG measurement and EUS-guided liver biopsy sampling using a single-center experience.
Methods:
Patients with suspected liver disease or cirrhosis were enrolled prospectively from 2020 to 2021. EUS-PSG was measured by calculating the difference between the mean portal pressure and the mean hepatic vein pressure. PH was defined as PSG >5 mm Hg and clinically significant PH as PSG ≥10 mm Hg. The primary outcomes were procedural technical success rate and correlation of EUS-PSG with fibrosis stage obtained from concurrent EUS-guided liver biopsy sampling and the correlation of EUS-PSG with patients' imaging, clinical, and laboratory findings. The secondary outcome was occurrence of procedural adverse events (AEs).
Results:
Twenty-four patients were included in the study. PSG measurement and EUS-guided liver biopsy sampling were successful in 23 patients (technical success rate of 96%) and 24 patients (100% success), respectively. Analysis revealed a significant association between both PSG and liver stiffness measured on transient elastography (P = .011) and fibrosis-4 score (P = .026). No significant correlation was found between the fibrosis stage on histology and measured PSG (P = .559). One mild AE of abdominal pain was noted. Additionally, EUS-PSG was predictive of clinically evident PH.
Conclusions:
Simultaneous EUS-PSG measurement and EUS-guided liver biopsy sampling were both feasible and safe and correlated with clinically evident PH and noninvasive markers of fibrosis.