Related Experiment Video
Updated: Oct 10, 2025

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Detection of COVID-19 Using Heart Rate and Blood Pressure: Lessons Learned from Patients with ARDS
Abstract:
The world has been affected by COVID-19 coronavirus. At the time of this study, the number of infected people in the United States is the highest globally (31.2 million infections). Within the infected population, patients diagnosed with acute respiratory distress syndrome (ARDS) are in more life-threatening circumstances, resulting in severe respiratory system failure. Various studies have investigated the infections to COVID-19 and ARDS by monitoring laboratory metrics and symptoms. Unfortunately, these methods are merely limited to clinical settings, and symptom-based methods are shown to be ineffective. In contrast, vital signs (e.g., heart rate) have been utilized to early-detect different respiratory diseases in ubiquitous health monitoring. We posit that such biomarkers are informative in identifying ARDS patients infected with COVID-19. In this study, we investigate the behavior of COVID-19 on ARDS patients by utilizing simple vital signs. We analyze the long-term daily logs of blood pressure (BP) and heart rate (HR) associated with 150 ARDS patients admitted to five University of California academic health centers (containing 77,972 samples for each vital sign) to distinguish subjects with COVID-19 positive and negative test results. In addition to the statistical analysis, we develop a deep neural network model to extract features from the longitudinal data. Our deep learning model is able to achieve 0.81 area under the curve (AUC) to classify the vital signs of ARDS patients infected with COVID-19 versus other ARDS diagnosed patients. Since our proposed model uses only the BP and HR, it would be possible to review data prior to the first reported cases in the U.S. to validate the presence or absence of COVID-19 in our communities prior to January 2020. In addition, by utilizing wearable devices, and monitoring vital signs of subjects in everyday settings it is possible to early-detect COVID-19 without visiting a hospital or a care site.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Acute Coronary Syndrome III: Diagnostic Studies
Cardiopulmonary Resuscitation III: AED Use
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: