Estimating the Center of Rotation of Tomographic Imaging Systems with a Limited Number of Projections
Abstract:
For a tomographic imaging system, image reconstruction quality is dependent on the accurate determination of coordinates for the true center of rotation (COR). A significant COR offset error may introduce ringing, streaking, or other artifacts, while smaller error in determining COR may blur the reconstructed image. Well known COR correction techniques including image registration, center of mass calculation, or reconstruction evaluation work well under certain conditions. However, many of these methods do not consider various real-world cases such as a tilted sensor or non-parallel projections. Furthermore, a limited number of projections introduces stripe artifacts into the image reconstruction that interfere with many of these classic COR correction techniques. In this paper, we propose a revised variance-based algorithm to find the correct COR position automatically prior to tomographic reconstruction. The algorithm was tested on both simulated phantoms and acquired datasets, and our results show improved reconstruction accuracy.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Kinematic Equations for Rotation
For instance, imagine a point A on a rigid body engaged in circular motion. The translational velocity of this particular point can be calculated by taking the time derivatives of the displacement equation, which essentially measures the...
Centroid for the Paraboloid of Revolution
The centroid for the paraboloid of revolution is the point where all the mass of the paraboloid is concentrated. This centroid is important for engineering applications, as it determines how forces are...