Application of correlated component analysis to dynamic PET time-activity curves denoising
Abstract:
Positron emission tomography (PET) is a physiological, non-invasive imaging technique, which forms an essential part of nuclear medicine. The data obtained in a PET scan represent the concentration of an administered radiotracer in tissues over time. Quantitative analysis of PET data makes possible the assessments of in-vivo physiological processes. The Logan graphical analysis (LGA) is one of the methods that are used for quantitative analysis of PET data. LGA transforms PET data into a simple linear relationship. The slope of the LGA linear relationship is a physiological quantity denoting receptor availability. This quantity is termed distribution volume ratio (DVR). LGA-based estimates of the DVR are negatively affected by the noise in PET data -leading to the DVR being underestimated. A number of approaches proposed to address this issue have been observed to reduce the bias at the cost precision. An alternative regression method, least-squares cubic (LSC), was recently applied to estimate the DVR in order to reduce the bias. LSC was observed to reduce the bias in the LGA-based estimates. However, slight increases were also observed in the variance of the LSC-based estimates. This calls for methods to act against the variance in the LSC-based estimates. In this study, an alternative method is applied for tTAC denoising. This method is referred to as correlated component analysis (CorrCA). CorrCA transform the data by searching for dimensions of maximum correlation. This technique is closely related to other well-known methods such as principal component analysis and independent component analysis. In this study, the data were denoised by CorrCA (to act against the variance in the estimate) and the DVR was estimated by LSC, which provides for minimal bias. The resulting method LSC-CorrCA, gave less-biased estimated with increased precision. This was observed for both simulation results as well as for clinical data, both for 11C Pittsburgh compound B. Simulation data revealed reduced variances in LCS-CorrCA-based estimates, and the clinical data showed improved contrast between gray and white matter regions.Clinical Relevance-Improved DVR estimates would ease the interpretation of medical images, which will in turn positively influence the clinical processes, from diagnosis to treatment and follow-ups.
Related Concept Videos
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Noncompartmental Analysis: Mean Residence Time
After the administration of a drug through intravenous bolus injection, the drug molecules are distributed throughout the body and remain there for varying periods. The MRT represents the average time these drug molecules stay in the...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Discrete Fourier Transform