Ultrasound-based Pulse Wave Velocity Evaluation in Mice
Published on: February 14, 2017
Pulse wave velocity measurement along the ulnar artery in the wrist region using a high frequency ultrasonic array
Abstract:
A pulse wave velocity (PWV) measurement method performed above a small blood vessel using an ultrasonic probe is studied and reported in this paper. These experimentations are carried out using a high-frequency probe (14-22 MHz), allowing a high level of resolution compatible with the vessel dimensions, combined with an open research ultrasound scanner. High frame-rate (HFR) imaging (10 000 frames per second) is used for a precise PWV estimation. The measurements are performed in-vivo on a healthy volunteer. The probe is placed above the ulnar artery on the wrist in order to make longitudinal scans. In addition to conventional duplex ultrasound evaluation, the measurement of the PWV using this method at this location could strengthen the detection and diagnosis of cardiovascular diseases (CVDs), in particular for arm artery diseases (AADs). Moreover, these experimentations are also carried out within the scope of a demonstration for a potential miniaturized and wearable device (i.e., a probe with fewer elements, typically less than 32, and its associated electronics). The study has shown results coherent with expected PWV and also promising complementary results such as intima-media thickness (IMT) with spatiotemporal resolution on the order of 6.2 μm and 0.1 ms.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse Assessment Sites
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...