Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Contactless video-based photoplethysmography technique comparison investigating pulse transit time estimation of
Background:
Non-contact measurement of physiological vital signs, such as blood pressure (BP), by video-based photoplethysmography (vPPG) is a potential means for remote health monitoring. However, the signal-to-noise ratio of cardiovascular signals within the vPPG is very low.
Objective:
This study investigates the potential of BP estimation from vPPG.
Methods:
In 10 healthy volunteers (4 females, 28 ± 7 years), continuous electrocardiogram, finger BP and video of the face and palm of the hand were recorded. BP was varied by isometric hand grip exercise and leg ischemia. Four vPPG methods were compared: (i) averages of the green (GREEN) color intensity; (ii) the best linear combination of color channels using independent component analysis (ICA); (iii) a linear combination of chrominance-based (CHROM) signal by standardizing the skin color profile; (iv) plane orthogonal to the skin tone (POS) as vPPG signal. These were applied to 14 regions of interest (ROIs) on the face and 5 ROIs on the palm. Pulse transit time (PTT) between ROIs, for all permutations, were calculated and the correlation with BP quantified.
Results:
A significant, negative PTT-BP correlation was defined as success. A maximum success rate of 80% was achieved, occurring for the GREEN, POS and ICA methods only for specific ROIs within the face, but not for any permutation using the hand.
Conclusions:
These results indicate that the use of vPPG for estimation of BP will be challenging. A combination of different vPPG methods and within-face ROIs may yield useful information.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse
The pulse serves as a clinical...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring pulse