Related Experiment Video
Updated: Oct 10, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
A novel few-views arrangement of the fixed X-ray tubes for tomosynthesis
Kensuke Hori1, Takahisa Koike1, Kiichi Tadano1
1Kyorin University Graduate School of Health Sciences, 5-4-1, Shimorenjaku, Mitaka, Tokyo 181-8612, Japan.
Purpose:
Tomosynthesis is a technique that reconstructs a volume image from limited-angle projection data. In conventional tomosynthesis, the examination time is long, so it can be difficult for patients to hold their breath during certain examinations, such as chest imaging. Few-views tomosynthesis, which uses a linear arrangement of fixed X-ray tubes and enables an image to be obtained within 1 s, was found to be useful in the clinical setting in our previous study. In the present study, we attempted to develop a novel few-views tomosynthesis system that can obtain images with an improved image quality.
Methods:
A novel few-views arrangement of X-ray tubes was proposed and the image reconstruction method with regularization term was applied. The linear arrangement was used for the X-ray tube arrangement in our previous few-views tomosynthesis, in contrast, a circular arrangement was proposed in this study. The validation of this system was conducted with a numerical simulation and a real data experiment.
Results:
The wider the scan angle, the more the object shadow spreads from "in-plane", allowing for artifact suppression. In the circular arrangement, the constant scan angle of θ is used, but in the linear arrangement the scan angle is set from 0 to θ. The artifacts in "out-of-plane" were more strongly suppressed in the circular arrangement than in the linear arrangement.
Conclusions:
Artifacts spreading in the z-direction were more strongly suppressed using the circular arrangement than the linear arrangement. Therefore, the circular arrangement was deemed appropriate for few-views tomosynthesis.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT

