The Intra-Aortic Balloon Pump
Published on: February 5, 2021
The influence of intra-aortic balloon counter pulsation on central venous blood oxygen saturation
Ayman Mohamed1,2, Sameh Aboulnaga1,3, Fayez Hamwi1
1Department of Cardiothoracic Surgery/Cardiac Anaesthesia and ICU, Heart Hospital, 36977Hamad Medical Corporation, Doha, Qatar.
Objectives:
We aim at identifying the changes in venous blood saturation values that associates intra-aortic balloon pump (IABP) in cardiac surgery patients with reduced left ventricular function (LVF).
Methods:
A retrospective observational study was conducted in a cardiothoracic intensive care unit (CTICU) in a tertiary cardiac center over 5 years in Qatar. A total of 114 patients with at least moderate impairment of LVF with ejection fraction (EF) less than 40% were enrolled. According to the association of IABP, patients were segregated into two groups with and without IABP (groups 1, 40 patients and group 2, 74 patients). Sequential arterial and venous blood gases were analyzed. The primary outcome was to analyze the changes in the central venous saturation (ScvO2) in both groups and the secondary outcome was to analyze whether these changes affect the overall outcome in terms of intensive care unit (ICU) length of stay.
Results:
There was no significant difference between both groups with regard to age, preoperative EF, hemoglobin, and arterial oxygen saturation (SaO2) in blood gases. Patients with IABP have a higher cScvO2 when compared to the other group (71.5 ± 12.5 vs 63.5 ± 9.3, 68.3 ± 12.6 vs 60.1 ± 9.5, 62.7 ± 10.8 vs 55.63 ± 8.1, and 60.6 ± 7.6 vs 54.9 ± 8.1; p = 0.04, 0.05, 0.03, and 0.5, respectively). However, generalized estimating equations (GEE) analysis showed that compared with the participants showing that there is a decreasing trend in mean levels within the groups during follow-ups, overall difference between both groups' mean levels was not statistically significant.
Conclusions:
In this study, we observed that after cardiac surgeries, patients with IABP had non-significant higher ScvO2 when compared with a corresponding group with moderate impairment of LVF. Further prospective studies are required to validate these findings.
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...