Related Experiment Video
Updated: Oct 10, 2025

Intraoperative Gastroscopy for Tumor Localization in Laparoscopic Surgery for Gastric Adenocarcinoma
Published on: August 9, 2016
Real-time use of artificial intelligence for diagnosing early gastric cancer by magnifying image-enhanced endoscopy:
Xinqi He1, Lianlian Wu1, Zehua Dong1
1Department of Gastroenterology, Renmin Hospital of Wuhan University, Wuhan, China; Key Laboratory of Hubei Province for Digestive System Disease, Renmin Hospital of Wuhan University, Wuhan, China; Hubei Provincial Clinical Research Center for Digestive Disease Minimally Invasive Incision, Renmin Hospital of Wuhan University, Wuhan, China.
Background And Aims:
Endoscopy is a pivotal method for detecting early gastric cancer (EGC). However, skill among endoscopists varies greatly. Here, we proposed a deep learning-based system named ENDOANGEL-ME to diagnose EGC in magnifying image-enhanced endoscopy (M-IEE).
Methods:
M-IEE images were retrospectively obtained from 6 hospitals in China, including 4667 images for training and validation, 1324 images for internal tests, and 4702 images for external tests. One hundred eighty-seven stored videos from 2 hospitals were used to evaluate the performance of ENDOANGEL-ME and endoscopists and to assess the effect of ENDOANGEL-ME on improving the performance of endoscopists. Prospective consecutive patients undergoing M-IEE were enrolled from August 17, 2020 to August 2, 2021 in Renmin Hospital of Wuhan University to assess the applicability of ENDOANGEL-ME in clinical practice.
Results:
A total of 3099 patients undergoing M-IEE were enrolled in this study. The diagnostic accuracy of ENDOANGEL-ME for diagnosing EGC was 88.44% and 90.49% in internal and external images, respectively. In 93 internal videos, ENDOANGEL-ME achieved an accuracy of 90.32% for diagnosing EGC, significantly superior to that of senior endoscopists (70.16% ± 8.78%). In 94 external videos, with the assistance of ENDOANGEL-ME, endoscopists showed improved accuracy and sensitivity (85.64% vs 80.32% and 82.03% vs 67.19%, respectively). In 194 prospective consecutive patients with 251 lesions, ENDOANGEL-ME achieved a sensitivity of 92.59% (25/27) and an accuracy of 83.67% (210/251) in real clinical practice.
Conclusions:
This multicenter diagnostic study showed that ENDOANGEL-ME can be well applied in the clinical setting. (Clinical trial registration number: ChiCTR2000035116.).
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to: