Related Experiment Video
Updated: Oct 10, 2025

Identification of Rare Bacterial Pathogens by 16S rRNA Gene Sequencing and MALDI-TOF MS
Published on: July 11, 2016
Substantial Improvement in Nontuberculous Mycobacterial Identification Using ASTA MicroIDSys Matrix-Assisted Laser
Junhyup Song1, Shinyoung Yoon1, Yongha In2
1Department of Laboratory Medicine and Research Institute of Bacterial Resistance, Yonsei University College of Medicine, Seoul, Korea.
Abstract:
Identifying Mycobacterium using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is challenging. We evaluated the performance of MALDI-TOF MS in identifying nontuberculous mycobacteria (NTM) using the ASTA MicroIDSys system (ASTA Inc., Suwon, Korea) with the MycoDB v1.95s and upgraded MycoDB v2.0-beta databases. We tested 124 NTM isolates collected from Ogawa medium at Severance Hospital, Seoul, Korea, between January and April 2019. MicroIDSys scores were categorized into three groups: ≥140, reliable identification; 130-139, ambiguous identification; and <130, invalid identification. To validate the results, we used the reverse blot hybridization assay (Molecutech REBA MycoID, YD Diagnostics Corp., Korea). Initial analysis using MycoDB v1.95s resulted in 26.6% (33/124) reliable, 43.5% (54/124) ambiguous, and 29.8% (37/124) invalid identifications. Re-analysis using the upgraded MycoDB v2.0-beta database resulted in 94.4% (117/124) reliable, 4.0% (5/124) ambiguous, and 1.6% invalid (2/124) identifications. The percentage of reliable identifications that matched with the reference increased from 26.6% (33/124) with MycoDB v1.95s to 93.5% (116/124) with MycoDB v2.0-beta. The upgraded databases enable substantially improved NTM identification through deep learning in the inference algorithm and by considering more axes in the correlation analysis. MALDI-TOF MS using the upgraded database unambiguously identified most NTM species. Our study lays a foundation for applying MALDI-TOF MS for the simple and rapid identification of NTM isolated from solid media.
Related Concept Videos
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...
Modern Molecular Taxonomy
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...