Related Experiment Video
Updated: Oct 10, 2025

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry
Published on: August 1, 2017
Self-Optimization of Continuous Flow Electrochemical Synthesis Using Fourier Transform Infrared Spectroscopy and Gas
Jie Ke1, Chuang Gao1,2, Ana A Folgueiras-Amador3
1School of Chemistry, 6123University of Nottingham, Nottingham, UK.
Abstract:
A continuous-flow electrochemical synthesis platform has been developed to enable self-optimization of reaction conditions of organic electrochemical reactions using attenuated total reflection Fourier transform infrared spectroscopy (ATR FT-IR) and gas chromatography (GC) as online real-time monitoring techniques. We have overcome the challenges in using ATR FT-IR as the downstream analytical methods imposed when a large amount of hydrogen gas is produced from the counter electrode by designing two types of gas-liquid separators (GLS) for analysis of the product mixture flowing from the electrochemical reactor. In particular, we report an integrated GLS with an ATR FT-IR probe at the reactor outlet to give a facile and low-cost solution to determining the concentrations of products in gas-liquid two-phase flow. This approach provides a reliable method for quantifying low-volatile analytes, which can be problematic to be monitored by GC. Two electrochemical reactions the methoxylation of 1-formylpyrrolidine and the oxidation of 3-bromobenzyl alcohol were investigated to demonstrate that the optimal conditions can be located within the pre-defined multi-dimensional reaction parameter spaces without intervention of the operator by using the stable noisy optimization by branch and FIT (SNOBFIT) algorithm.
More Related Videos
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Interfacial Electrochemical Methods: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Electrogravimetric Analysis: Overview
To test the completeness of the...

