Related Experiment Video
Updated: Oct 10, 2025

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
The reliability of CT numbers as absolute values for diagnostic scanning, dental imaging, and radiation therapy
Yazan Al-Hayek1, Kelly Spuur2, Xiaoming Zheng2
1Faculty of Applied Health Sciences, The Hashemite University, Zarqa 13133, Jordan; School of Dentistry and Health Sciences, Charles Sturt University, Wagga Wagga, NSW 2650, Australia.
Background And Purpose:
The purpose of this review was to examine the reported factors that affect the reliability of Computed Tomography (CT) numbers and their impact on clinical applications in diagnostic scanning, dental imaging, and radiation therapy dose calculation.
Methods:
A comprehensive search of the literature was conducted using Medline (PubMed), Google Scholar, and Ovid databases which were searched using the keywords CT number variability, CT number accuracy and uniformity, tube voltage, patient positioning, patient off-centring, and size dependence. A narrative summary was used to compile the findings under the overarching theme.
Discussion:
A total of 47 articles were identified to address the aim of this review. There is clear evidence that CT numbers are highly dependent on the energy level applied based on the effective atomic number of the scanned tissue. Furthermore, body size and anatomical location have also indicated an influence on measured CT numbers, especially for high-density materials such as bone tissue and dental implants. Patient off-centring was reported during CT imaging, affecting dose and CT number reliability, which was demonstrated to be dependent on the shaping filter size.
Conclusion:
CT number accuracy for all energy levels, body sizes, anatomical locations, and degrees of patient off-centring is observed to be a variable under certain common conditions. This has significant implications for several clinical applications. It is crucial for those involved in CT imaging to understand the limitations of their CT system to ensure radiologists and operators avoid potential pitfalls associated with using CT numbers as absolute values for diagnostic scanning, dental imaging, and radiation therapy dose calculation.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...